menu_book

Knowledge Base

Documentation, guides, and resources for Noldus products.

FaceReader Data in The Observer XT – Finding Event Markers and Stimuli After Importing an .odx File

Last updated: Nov 26, 2026

Problem

You imported FaceReader data into The Observer XT and cannot find the event markers and stimuli, or want to leave intervals with an event marker out of the analysis.

Details

FaceReader exports an .odx file that you import into an Observer XT observation. Event markers and stimuli are imported as separate event logs, so they are easy to overlook. Based on tickets for FaceReader 9.

Solution

  1. Export your FaceReader analysis as an .odx file for The Observer.
  2. In Observer XT, choose File > Import Data and select the .odx file to import it into the observation.
  3. To find event markers and stimuli: in the project explorer on the left, expand the observation, then expand Event Files. Click an event file to see its events. The analysis and visualization include all event logs.
  4. To align the FaceReader data with other data in the observation, use the offset feature.
  5. To leave out intervals with an event marker, use Select Intervals By Behaviors in the Data Profile and select No Event Marker.
  6. In the FaceReader Detailed Log export, event markers and stimuli are in the rightmost columns.

shopping_bag
check_circle

Thank you!

We'll get back to you shortly.

error

Please correct the following errors:

error

error

error

error

By clicking Submit, you consent to Noldus processing your data as described in our privacy policy.

check_circle

Thank you for registering!

We look forward to seeing you at the NoldusViso launch event.

error

Please correct the following errors:

error

error

error

error

error

By clicking Register, you consent to Noldus processing your data as described in our privacy policy.