Observer XT Data Profile: Analysing Separate Experimental Segments or Task Conditions With Interval Selection
Last updated: Nov 26, 2026
Applies to: Observer XT (version not stated in the tickets; menu paths from the Observer XT 17 manual)
Problem
Your observation contains multiple experimental segments (for example, a baseline period, a stimulus video, a task session, and a second baseline), and you want to analyse each segment separately rather than the entire observation.
Details
In one ticket, a customer combined a baseline, a stimulus video and gaming sessions in one observation and wanted to analyse the segments separately. Support advised using the interval options of a Data Profile, based either on clock time or on scored behaviors (for example, a coding scheme that contains the task or segment names). A second ticket describes filtering by group with the selection boxes By Subjects, By Behaviors, By Modifiers and by independent variables. Neither ticket states the Observer XT version. The menu names below follow the Observer XT 17 manual (Select Data for Analysis). Related published articles: 45305 (restricting analysis to a time window) and 45991 (exporting external data for annotated task intervals).
Solution
- Code each segment or task condition as a state event (a behavior with a start and a stop) in your observation, for example 'Baseline_1', 'Stimulus' or 'Gaming_1'.
- Choose Analyze > Select Data > New Data Profile. This opens the Data Selection window. To open an existing profile, choose Analyze > Select Data > New/Open Data Profile.
- Insert a By Behaviors interval box with the segment behavior (for example 'Gaming_1') in the sequence between the Start box and the Results box. The analysis then covers the events scored while that state was active (Select Intervals by Behaviors).
- Save the Data Profile with a descriptive name, for example 'Analysis - Gaming session 1'.
- Repeat steps 3 and 4 for each segment you want to analyse separately, and select the matching Data Profile before you run the analysis.
- If your segments are defined by fixed clock times instead of a coded behavior, use the manual interval selection (Select Intervals by Manual Selection) instead of a behavior box.
- For the other interval options, see Select Data for Analysis in the Observer XT Help.