Two behaviors share the same key code in Observer XT coding scheme
Last updated: Nov 23, 2026
Problem
You receive an error when trying to start or use a coding scheme because two behaviors have been assigned the same key code, even though you did not intentionally change anything in the coding scheme.
Details
Observer XT requires every behavior in a coding scheme to have a unique key code. If two behaviors end up with the same key code — even without an obvious change on your part — the conflict will prevent normal coding. This can surface as an error message when starting an observation or when attempting to record a behavior. Editing the coding scheme to resolve the conflict requires a main (full) Observer XT license; a Coder (OC) license does not allow coding scheme modifications.
Solution
1. Open Observer XT and load your project.
2. In the menu bar, go to **Setup** > **Unlock configuration**. (This option requires a main Observer XT license. If you only have a Coder license, you will not see this option — contact Noldus at https://noldus.com/app/home to discuss your license options.)
3. Once configuration is unlocked, open your coding scheme.
4. Review each behavior's assigned key code to identify the two behaviors that share the same key code.
5. Click on one of the conflicting behaviors and assign it a unique key code that is not already used by any other behavior or modifier in the scheme.
6. Save the coding scheme.
7. Lock the configuration again if appropriate, then test by starting a new observation to confirm the error no longer appears.
Note: Observer XT does not currently log what caused identical key codes to appear. The important step is simply to correct the conflict so you can resume coding.