EthoVision XT 18 – 'Sample Grabber Error. Reinstall the Application' After Installing From the Package File
Last updated: Nov 26, 2026
Applies to: EthoVision XT 18
Problem
After installing EthoVision XT 18 you receive the message 'Sample grabber error. Reinstall the application' when you configure the video source in the experiment settings. Reinstalling or using the repair option of the installer does not help, and the camera works in the Pylon viewer.
Details
Support advised that the EthoVision XT - Package file installs only EthoVision itself and not the prerequisite files, such as the Sample Grabber. The EthoVision XT - Setup file installs the other components. In a second ticket the error was solved by reinstalling EthoVision XT 18, which made the installer check for and download the latest version of the frame grabber. Reported with EthoVision XT 18. A different cause of a SampleGrabber error is described in the published article on a missing or conflicting Noldus SampleGrabber component.
Solution
- Check which file you used to install. Use the EthoVision XT - Setup file, not the EthoVision XT - Package file. Extract the downloaded ZIP file first (right-click > Extract All), then run the Setup file in the extracted folder.
- Run the Setup file again. It installs the components that are needed, including the Sample Grabber.
- If you get an error while running the Setup file, send the installation log file to Noldus Support.