All Camera Feeds Show Errors - Diagnosing with Video Settings
Last updated: Nov 26, 2026
Applies to: MediaRecorder 6 (reported)
Problem
When you open MediaRecorder, all camera feeds show an error at the same time and no video is displayed.
Details
Two tickets on MediaRecorder 6: all cameras showed an error at once, and an 'Initialization error detected with Video 1. Please check or reinstall codecs or drivers.' message. Support suggested quick tests: setting the audio device of the videos to No audio in Video Settings, and checking that a camera answers in a web browser. If the video image comes back with No audio, the audio source is the problem, for example an unplugged audio cable. Restarting the PC and the cameras was also advised. The cause was not confirmed in the tickets.
Solution
- Restart the PC. Also power-cycle the cameras: switch them off for at least 10 seconds, switch them on, and wait one to two minutes before you open MediaRecorder.
- In MediaRecorder, click Video Settings (File > Video Settings). Note which audio device is selected for each video and whether the checkbox to use audio device 1 for all videos is selected.
- Set the audio device to No audio for each video and click OK or refresh. If the video image returns, the problem is with the audio source (for example, an audio cable is unplugged or the wrong device is selected). Check and reseat the audio cables.
- To check that a camera is connected and powered, click the camera icon next to the first camera in Video Settings. For Noldus-configured systems the camera addresses typically start at 192.168.200.1 for the first camera, 192.168.200.2 for the second, and so on. Enter the address in a web browser. If it connects or asks for a user name and password, the camera is connected and powered.
- If the errors continue, contact Noldus Support and send a screenshot of the error and of your audio device settings.