menu_book

Knowledge Base

Documentation, guides, and resources for Noldus products.

FaceReader Software Interface Unresponsive (Only EULA Button Clickable)

Last updated: Oct 29, 2026

Problem

After launching FaceReader, the software interface is almost entirely unresponsive. The only interactive element is the end-user license agreement (EULA) button. Force-quitting, reopening, and restarting the computer do not resolve the issue.

Details

Affects systems using a hardware dongle (USB license key) for activation. The interface loads partially but cannot proceed without a valid dongle signal. Font size or display settings are unlikely contributors.

Solution

1. Remove the hardware dongle from the USB port.
2. Wait a few seconds, then firmly re-insert the dongle.
3. Relaunch FaceReader.
4. If the dongle is not recognized, try a different USB port.
5. If the issue continues, verify the dongle drivers are installed and the dongle LED is active.

shopping_bag